Cable Cutters
ISOTOOLS also insists on the best quality for raw material "Made in Germany" for the insulated Cable Cutter 1000 V and VDE Cable Cutterrs.
All insulated Cable Cutters are manufactured according to the standard IEC/EN60900:2012.
The development and production is subject to high quality standards in accordance with the standard so we can guarantee best and long lasting handling for the user.
Our insulated Cable Scissors 1000 V are designed in various designs for different areas of activity and guarantee maximum safety when working under voltage up to 1000 V.
In special tool making it is, of course, also possible to produce the required tools according to your wishes. We would be pleased to advise you on the selection and implementation.
Of course, it is also possible to provide your company logo on the tools.
- Cutters with excellent cutting performance for pinch-free cutting of steel-aluminum cords up to 120 sq. mm, Copper-and Aluminumcables
- opening width approx. 20 mm
- Knife head interchangeable
- without leverage Transmission
- from highly refined special Steel forged
- According to the latest Norm EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test Voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
length / mm | weight / g | Norm |
---|---|---|
600 | 1.800 | ![]() |
Spare Head | 335 |
- for pinch – free cutting of Copper-and Aluminumcables
up to 150 / 180 mm² - opening width Ø 26 / 33 mm
- replaceable Knife head
- with leverage Transmission
- Blades made from special alloy Steel forged
- not for Steel Wire and hard-drawn Copper Cables
- According to the latest Norm EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test Voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
length / mm | weight / g | Norm |
---|---|---|
600 | 2.700 | ![]() |
700 | 3.300 | ![]() |
Spare Head for 600 | 320 | |
Spare Head for 700 | 340 | |
Storing Bag for 600/700 | 240 |
- for pinch-free cutting of Copper-and Aluminumcables up to 150 mm²
- opening width approx. Ø 27 mm
- Cutter Head made of Vanadium Steel
- low effort and easy
- clean cut due to new geometrical Blade
- adjustable screw mechanism
- low weight
- short construction
- not for Steel wire and hard-drawn Copper Cables
- According to the latest Norm EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test Voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
length / mm | weight / g | Norm |
---|---|---|
215 VDE | 360 | ![]() |
VDE „Made in Germany“
- High-quality 2-colour multilayered insulation "Made in Germany"
- for pinch-free cutting of Copper-and Aluminumcables
- single Wire up to 25 sq. mm
- multi-Wire up to 50 sq. mm
- fine Wire up to 70 sq. mm
- opening width Ø 22 mm
- cutting Hardness: approx. 53-55 HRC
- precision cutting edges for a smooth and clean cut
- with trap Protection
- with adjustable screw
- hardened Blades with precision grinding
- easy cutting with one-hand operation due to high translation
- solid version from Vanadium Steel
- forged, oil-hardened
- not for Steel wire and hard-drawn Copper cables
- According to the latest Norm VDE / EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test Voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
length / mm | weight / g | Norm |
---|---|---|
215 VDE | 360 | ![]() |
- High-quality 2-colour multilayered insulation "Made in Germany"
- for splitting cross-sections of up to 35 sq. mm soft Multi-Wire Copper and Aluminumwires
- opening width Ø 17 mm
- drop forged
- precision-ground and with adjustable screw transmission
- not for Steel Wire and hard-drawn Copper Cables
- According to the latest Norm EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test Voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
length / mm | weight / g | Norm |
---|---|---|
165 | 240 | ![]() |
- High-quality 2-colour multilayered insulation "Made in Germany"
- for Copper- and Aluminumcable Single-and Multi wire up to 50 sq. mm
- opening width Ø 20 mm
- precision ground with excellent cutting performance for one-hand use
- forged from special Tool Steel
- with leverage transmission
- not suitable for Steel Wire or hard Copper Wire
- According to the latest Norm EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test Voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
length / mm | weight / g | Norm |
---|---|---|
200 | 365 | ![]() |
- High-quality 2-colour multilayered insulation "Made in Germany"
- for Aluminum- and Copperwires
- multi Wire up to 50 sq. mm
- forged from tool steel
- easy cutting
- dropped forged
- oil hardened
- According to the latest Norm EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test Voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
length / mm | weight / g | Norm |
---|---|---|
240 | 455 | ![]() |
- High-quality 2-colour multilayered insulation "Made in Germany"
- opening width 12 mm
- Cutting capacity: Wire rope 1570N / mm, 9 mm Ø,
Copper (soft) 16 mm Ø - Cutting induction hardened and chrome plated
- from alloyed tool Steel
- According to the latest Norm EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test Voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
length / mm | weight / g | Norm |
---|---|---|
700 | 2.400 | ![]() |
- High-quality 2-colour multilayered insulation "Made in Germany"
- two hand cutter with double-pivoted Eccentric power unit
- almost unbreakable dovetailing of rotary knife and tooth blade
- cuts stranded + fine Copper/Aluminum-Wire up to Ø 62 mm
or Ø 80 mm - also separates cables with thin steel sheathing or Steel plate reinforcement in the outside of the cable
- not to be used on Steel Wire!
- high strength special Steel
- locking lever
- According to the latest Norm EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test Voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
Ø mm | mm²* | length / mm | weight / g | Norm |
---|---|---|---|---|
62 | 840 | 370 | 2.200 | ![]() |
80 | 1.000 | 550 | 3.150 | ![]() |
* Cutting Capacity |
- High-quality 2-colour multilayered insulation "Made in Germany"
- for Copper-and Aluminum-Wire
- one-hand-operation
- step-wise and burr-free cutting
- high strength special Steel
- According to the latest Norm EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test Voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
multi wire / mm | single wire / mm | length / mm | weight / g | Norm |
---|---|---|---|---|
52 | 25 | 330 | 942 | ![]() |
- High-quality 2-colour multilayered insulation "Made in Germany"
- through spring reverse
- cutting blade can be brought back
- cuts stranded + fine Copper/Al-Wwire
- one-hand operation
- locking lever
- not to be used on Steel Wire
- can also be delivered without insulated head
- high strength special Steel
- According to the latest Norm EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test Voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
length / mm | mm²* | weight / g | Norm | |
---|---|---|---|---|
290 | 185 Al. or 150 Co. | 1.000 | ![]() | |
310 | 240 Al. oder 180 Co. | 1.150 | ![]() | |
* Cutting Capacity |
- High-quality 2-colour multilayered insulation "Made in Germany"
- replaceable Head
- cuts up to 11 mm
- with steel tube leg and Extender adjustment
- Head from special Steel
- induction hardened
- According to the latest Norm EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test Voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
length / mm | weight / g | Norm |
---|---|---|
610 | 2.700 | ![]() |
- High-quality 2-colour multilayered insulation "Made in Germany"
- with leverage transmission
- only to be used on Copper-and Aluminumcable
- adjustable length from 350 mm up to 550 mm
- replaceble Head
- According to the latest Norm EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test Voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
length / mm | Ø mm | mm²* | weight / g | Norm |
---|---|---|---|---|
350-550 | 31 | 185 | 2.000 | ![]() |
Spare Head | - | - | 300 | - |
* Cutting Capacity |
- High-quality 2-colour multilayered insulation "Made in Germany"
- from special Tools Steel
- Shears for small radii and difficult to access
- 100% power with little effort
- lean design allows better access to hard-to-reach places at the same time on workpiece and material.
- hand forged, oil hardened
- According to the latest Norm EN 60900:2012 / IEC 60900:2012
Tools with double triangle are tested piece-by-piece with a test voltage 10.000 Volt and certificated highest possible safeness for working on live parts up to 1.000 Volt.
All Safety Tools are stamped and signed according their Norm:
- IEC / EN 60900: 2012 or additional with VDE / GS also with Item Number, Size, Manufacturing Year and Manufacturer, 1000V and Double Triangle respectively VDE-Sign.
- High quality PVC according to the REACH-Regulation and withstand the newest PAK-Inspection.
mm | Cutting length/mm | sheet thickness (600 N/mm²) | weight / g | Norm |
---|---|---|---|---|
180 | 20 | 1 mm | 220 | ![]() |